GT11 Series 1~3kVA online Rack UPS premium product delivers a robust power range of 1-3kVA, engineered to meet the rigorous demands of mission-critical sectors including government, finance, IT, education, transportation, broadcasting, medical, and energy industries. Featuring advanced 1P/1P operation with online double conversion technology, it ensures seamless power stability and uninterrupted performance. Boasting industry-leading high efficiency up to 96% and a unity output power factor (PF=1), it achieves unparalleled energy optimization and superior load adaptability for dynamic environments. With an exceptionally wide input voltage range of 110-300Vac and a rapid recharge capability (max charging current 12A), this system guarantees reliable operation even under extreme grid fluctuations, making it an ideal, future-proof solution for diverse power protection needs.
Des produits
Étiqueter:
Onduleur en ligne pour rack de la série GT11 de 1 à 3 kVA
● Power Factor: Supports efficient adaptation and energy optimisation for dynamic loads.
● Ultra-wide Input Voltage Range: Adaptable to extreme grid fluctuations.
● Fast Charging Capability: Shortening battery recharge time.
● Core Advantages: High reliability, grid compatibility, energy saving and high efficiency.
Haute efficacité jusqu'à 96%.
Sortie PF=1, adaptabilité de charge élevée.
Large plage de tension d'entrée de 110 ~ 300 V CA.
Courant de charge maximum jusqu'à 12A.
Government, Finance, IT, Education, Transportation, Broadcasting, Medical, Energy, etc.
Étiqueter:
Introduction
Paramètres
Télécharger
Modèle | GT1101BR | GT1101LR | GT1102BR | GT1102LR | GT1103BR | GT1103LR | |
Puissance nominale | 1kVA/1kW | 1kVA/1kW | 2kVA/2kW | 2kVA/2kW | 3kVA/3kW | 3kVA/3kW | |
Démarrage à froid | Sortie par défaut 50/60 Hz | ||||||
Plage de tension d'entrée | 110~300VAC;100%load@176VAC~276VAC,100%~50%power derating@110VAC~176VAC,50%load@276VAC~300VAC | ||||||
Facteur de puissance d'entrée | ≥0,99 | ||||||
Gamme de fréquences | 50/60±5Hz(default),±3Hz/±10Hz(settable) | ||||||
Facteur de puissance de sortie | 1.0 | ||||||
Sortir | Tension nominale | 220/230/240VAC,200/208VAC(PF=0.9) | |||||
Réponse de charge | ≤5%(0%-100%-0%step load) | ||||||
Le temps de récupération | ≤40ms(0%-100%-0%step load) | ||||||
Sortie THDu | ≤2%,Linear load;≤5%non-linear load according to IEC62040-3 | ||||||
Transfertime | Principal vers BAT | 0 | |||||
INV en BYP | 4 ms | ||||||
Efficiency (normal mode) | Max 96% | ||||||
Bruit (1 mètre) | 43dB@<60%load,47dB@>60%load | <50dB@<60%charge,<55dB@>60%charge | <50dB@<60%charge,<55dB@>60%charge | ||||
Surcharge | Normal | 102%~110%:30mins,110%~125%:10mins,125%~150%:30 seconds | |||||
Mode batterie | 102%~110%:1min,110%~125%:10 seconds,125%~150%:5 seconds | ||||||
Mode contournement | <130%:long time,130%~150%:10mins,150%~180%:5 seconds | ||||||
Batterie | Modèle | 12 V CC/9 Ah | Depend on external battery | 12 V CC/9 Ah | Depend on external battery | 12 V CC/9 Ah | Depend on external battery |
Quantité | 2/3 | 4/6 | 6/8 | ||||
Charge maximale | 1A | 1-12A (réglable) | 1A | 1-12A (réglable) | 1A | 1-12A (réglable) | |
Tension nominale | 24/36VDC | 48/72VDC | 72/96VDC | ||||
Standard | EPO,RS232 | ||||||
Option | SNMP card,AS400,USB,RS485,BMS by dry contact,Air filter | ||||||
Dimension ,W*D*H(mm) | 440*440*86 | 440*580*86 | 440*440*86 | 440*580*86 | 440*440*86 | ||
poids (kg) | 19 | 9.5 | 27.5 | 9.7 | 28 | 10 |
Produits connexes
-
Onduleur monophasé en rack de la série GT11 de 6 à 10 kVA
-
GTL31 Alimentation sans interruption en ligne basse fréquence 6~30 kVA
-
Onduleur en ligne pour rack de la série GT11Li de 1 à 3 kVA
-
GT-BU Alimentation de secours hors ligne sans interruption 600~2000VA
-
GT31 Tour d'alimentation sans interruption en ligne 10~20 kVA
-
Onduleur tour en ligne série GT11 1 à 3 kVA